TemperatureManager

Reads the board's three temperature sensors by name and keeps simple statistics. Source: TemperatureManager.h.

Name Sensor Read through
ESP32_INTERNAL The ESP32-S3's internal temperature sensor EspTemperature
NTC_THERMISTOR 10 kΩ NTC, B = 3950, 10 kΩ series resistor, 3.3 V AdcManager channel ESP32_NTC_THERMISTOR
MCP9700_THERMISTOR MCP9700 analog sensor AdcManager channel ADS7952_0_CH8 (needs HARDFOC_MCP9700_SUPPORT and a working ADS7952)

The manager starts if at least one sensor works; the others are left out and reads of them return SENSOR_NOT_FOUND. With a sensor missing it runs degraded: IsDegraded() is true, GetManagerError() says why, IsSensorReady(type) says which one, and GetSystemDiagnostics() never reports it healthy. It is the one manager that runs degraded rather than failing closed (Initialisation), because its sensors back each other up.

API

Call Notes
ReadTemperatureCelsius(name, float&), ReadTemperatureFahrenheit(name, float&) By name
ReadInternalTemperature(float&), ReadNtcTemperature(float&), ReadMcp9700Temperature(float&) Shortcuts for the three names
GetSystemTemperatureStats(min, max, avg) Reads every registered sensor and summarises
GetSensorCount(), GetSensorEntry(name) Registered sensors; TempEntry keeps the last reading and counters
GetLastError(), GetSystemDiagnostics(TempSystemDiagnostics&), DumpStatistics()

Example: board temperature with a fallback

#include "api/Flux.h"
#include "managers/TemperatureManager.h"

auto& temp = Flux::GetInstance().temp;
float c = 0.0f;
if (temp.ReadNtcTemperature(c) != TemperatureError::SUCCESS) {
    (void)temp.ReadInternalTemperature(c);  // the die sensor runs warmer than the board
}

Diagnostics

GetSystemDiagnostics() gives registered sensors, operation counters, and the minimum, maximum and average of the last readings. DumpStatistics() logs each sensor's last value and counters.

Pitfalls

  • Start-up order matters. The thermistors depend on AdcManager; if the ADC failed, only ESP32_INTERNAL registers and the manager reports DependencyNotReady.
  • The internal sensor measures the chip, not the valves or the board; it reads higher than ambient.
  • NTC values are fixed in code (B, series resistor, reference voltage). A different thermistor means changing TemperatureManager.cpp.