Troubleshooting

Symptoms you may see while bringing up a PF1550, their causes and the fix for each, cheapest check first.

Start with GetErrorFlags() after a failing call: DeviceNotFound or I2cRead / I2cWrite point at the bus, WrongDeviceId at the device, InvalidParam at the arguments, ProfileApply at a write the chip refused.

The chip does not answer

Symptom Cause Fix
EnsureInitialized() fails with DeviceNotFound No ACK at 0x08 Check the pull-ups to VDDIO, SDA and SCL not swapped, a common ground
Same, and the SDK logs an address of 0x10 8-bit address passed to a 7-bit API Pass 0x08; shift only inside your port if the SDK wants it
Same, on a programmed part OTP selects another address (0x09 to 0x0F) Scan the bus and pass the address to the constructor
WrongDeviceId Another device answers at 0x08, or DEVICE_ID is not 0x7C Read ReadDeviceId(); a PF1500 reads 0x78
Errors at high bus speed Clock above 400 kHz, or edges faster than 20 ns Run at 400 kHz or less; lower the master's drive strength
The ESP32 example reports no device Nothing wired, or the wrong pins Expected without hardware; otherwise check Kconfig PF1550_I2C_SDA_GPIO / SCL_GPIO

Writes do not change the rails

Symptom Cause Fix
SetSwVoltage() / SetSwVoltageMv() return false SW3, or an SW1 / SW2 declared DVS-disabled: those voltage registers are read-only. Or the voltage is off the DVS grid Change the set point in OTP, or declare DVS with SetSwDvsEnabled() if the part has it (Rails and OTP)
A rail reads far below the expected voltage A DVS-disabled code written with WriteRegister() to a DVS-enabled SW1 / SW2 (0x07 is 0.6875 V there) Use SetSwVoltageMv(); declare the mode with SetSwDvsEnabled()
A profile change has no effect after a reset The PMIC kept the previous values: an MCU reset does not reset it Power the PMIC down completely, then apply the profile again
The snapshot shows the old values after a profile The profile stopped at a failed write Check the return value and ProfileApply; the writes before it did happen
SetVbusCurrentLimitMa() returns false The value is not 10, 100, 500, 1000 or 1500 mA Write VBUS_INLIM_CNFG with code << 3 for other Table 58 values

Board symptoms (Portenta H7 and carriers)

Symptom Cause Fix
Carrier +3V3 or JTAG VTref is 0 V while the processor runs SW2 is off; with the default profile it also turns off in STANDBY Apply the carrier profile (SW2_CTRL = 0x0F)
LDO outputs are dead but the processor runs The LDO inputs hang off SW1, which is not up yet Use the carrier profile: SW1 first, then a 5 ms wait
USB does not enumerate after boot USB_VBUS_EN / USB_OTG_EN low, or STANDBY high SetPowerMode(PowerMode::Run) and SetUsbRails(true, true) before USB starts
The rails drop when the board idles STANDBY asserted, and the rail's STBY_EN bit is clear Drive STANDBY low, or set kStbyEn in the rail's control register

Faults and self-test

Symptom Cause Fix
A fault comes back right after ClearLatchedFaults() The cause is still there Read the SENSE register for the live state
INTB never goes low Every interrupt is masked (the reset value) SetInterruptMaskAll(false), or unmask one group

What software cannot check

Measure the rails, VBUS / OTG behaviour on USB-C and the I2C waveforms under load with instruments; the snapshot reports set points and status bits, not voltages.