Testing and CI

How the driver is checked: host unit tests against a model of the sensor, compiled documentation, ESP32 builds and static analysis, on every pull request.

Host unit tests

The tests build the real driver against a model of the FDO2-G2's command interface: it parses each command line, answers with the datasheet's own example values, and can stay silent, answer #ERRO, append a CRC suffix or deliver a reply later. Every command the driver sends is logged, so tests check what went on the wire.

cmake -S . -B build-host -DHF_FDO2_BUILD_TESTS=ON
cmake --build build-host
ctest --test-dir build-host --output-on-failure
File Covers
tests/test_driver.cpp Commands, scaling of every field, status, #ERRO codes, timeouts, CRC verification, the split exchange
tests/test_esp_uart.cpp The ESP32 example port: returns at the CR, keeps a partial line, honours the timeout
tests/esp_idf_stub/ A host model of the ESP-IDF UART and FreeRTOS calls that port uses
tests/mock_fdo2.hpp The sensor model and command log
tests/test_harness.hpp A dependency-free test registry and CHECK macros

Documentation snippets

Every C++ block on this site is included from tests/docs/, which the host build compiles (target hf_fdo2_doc_snippets) with the driver instantiated over the documented port. A change to the API that breaks a page breaks the build first.

CI workflows

Workflow What it checks
Host unit tests GCC and Clang build and run the tests and the doc snippets
ESP32 examples build Every app in examples/esp32/app_config.yml, for each listed ESP-IDF version and build type
C++ lint, C++ analysis clang-format, clang-tidy and cppcheck
Docs Strict site build, figure and generated-table drift, Doxygen, link check, Lighthouse budget
Markdown lint, YAML lint, link check Repository text files

The workflows call the shared, versioned workflows of hf-general-ci-tools and hf-espidf-ci-tools.

On hardware

The ESP32 examples are the hardware test: fdo2_minimal_example prints the identification and a reading every second over the serial monitor. In air at sea level, expect about 210 hPa and a status of 0 or 1.