Troubleshooting

Symptoms, causes and fixes, cheapest check first.

Symptom Cause Fix
sdoDownloadExpedited() returns false, nothing on the bus size is not 1, 2 or 4 Use the size of the object's type
Every call returns false Your send() fails: controller not started, bus-off, TX queue full Check the controller is initialised, termination (60 Ω between CAN_H and CAN_L with power off), bit rate
Frames on the bus, error frames follow No other node acknowledges, or bit rates differ Power the node; set the same bit rate everywhere (500 kbit/s on Vortex V1)
Node ignores NMT Wrong node ID, or the node has not finished booting Wait for its boot-up message (0x700 + node, one byte 0x00); check the ID
SDO abort from the node (0x580 + node, byte 0 0x80) Object missing, read-only, wrong size or value out of range Bytes 4 to 7 hold the CiA 301 abort code; check the EDS
CiA 402 drive does not reach Operation enabled A command was sent before the previous state was reached, or the drive is in Fault Read the statusword (0x6041) between steps; send Fault reset (0x0080) first
Motor does not move although enabled Mode of operation not set, or no target written Write 0x6060 and the target object for that mode